u
26 I/O (expandable to 38):
o
7 initiation inputs (discreet or
binary), dry contact or PNP
o
4 (expandable to 16 total)
programmable115V valve outputs (24 VDC optional)
o
5 addressable
proximity/pressure/limit switch inputs, dry contact or PNP
o
EHR, End of Hold Relay (sequence
completion), dry contact (NO or NC)
o
INIT./REWELD reads binary code or repeats
last weld, dry contact or PNP
o
WATER SAVER 115V valve output (remains ON 1
minute after last weld
o
3 assignable FAULT
outputs (MAJOR, MINOR, SPECIAL FAULT), dry contact or PNP
o
ES, Emergency Stop input, dry
contact or PNP
o
NO WELD, external dry contact or PNP and
also keypad selectable
o
Transformer over temperature input, dry contact or
PNP
o
SCR over temperature input, dry contact or PNP
u
Up to 45 LINKS (groups of functions) per
CHAIN
u
Up to 15 separate CHAINS (of 45 links
each for a total of 675 LINKS)
u
NO CODES TO LEARN, EVER!
u
DOES NOT USE LADDER LOGIC PROGRAMMING
or need a PC to program
u
Uses simple 17 button keypad (like a touch
tone phone) for all programming
u
70 complete
RWMA weld program memory, does not require linking
u
Ability to use the same weld PROGRAM at multiple
locations in a CHAIN
u
Can insert time delay and stop
sequences at desired places in the CHAIN
u
Full 32 character alpha/numeric readout in PLAIN
ENGLISH – NO CODES
|
u
Valve outputs 4 (expandable to 16 total) can be
independently designated in programs to:
o
Turn on or off at the start of
any link
o
Turn on or off at the end of
any link
u
Includes ANTI-TIEDOWN and ANTI-REPEAT
functions
u
Can be initiated in 5 different ways
o
Single Stage switch closure to select any of 7
CHAINS
o
Two Stage switch closure to select any of 3
CHAINS
o
Binary switch input to directly select
any of 70 programs
o
Binary switch input to select any of 15
CHAINS
o
Keypad Select non-chaining mode to
select a single weld schedule of the 70 available
u
One prox. input can be used for a LIGHT CURTAIN
(preprogrammed function)
u
Can control up to 15 SCR contactors in any
sequence (Multi-SCR option)
u
Can monitor Weld Current (option)
o
Single primary CT
o
Up to 15 secondary coils
u
Can read up to 16 different Differential
Pressure Transducers or Load Cells (option)
u
Keyboard Keylock is standard
u
Digital COUNTER displays individual welds
or completed parts
u
CHAINS can be manually or automatically run in 6
different modes:
o
Run the CHAIN one time and stop
o
Run the CHAINS sequentially
o
Run the CHAIN one time. If a proximity switch is
closed at the end, stop.
o
Run as above – At the end, go to the next CHAIN
o
Run a CHAIN 2-99 times and stop
o